Power meter display and control unit AC supply, IEEE bus

No matter whether you work in the lab or in production - the Microwave Power Meter R&S NRP is always the right choice. The versatility of the novel Power Meter Series R&S NRP is due to the newly developed sensors. These sensors are intelligent standalone instruments that communicate with the basic unit or a PC via a digital interface. The SMART SENSOR TECHNOLOGYTMnow implemented for the first time, sets new standards in terms of universality and accuracy.
Some highlights of the instrument:

Dynamic range up to 90 dB (sensor dependent)

Level range -67 dBm ... +45 dBm (sensor dependent)

Measurement speed: 1500 measurements per second in the buffered mode

Linearity uncertainty 1.5 % (20 to 25 C, f = 100 MHz to 4 GHz)

    * Precise average power measurements irrespective of modulation type and bandwidth
    * Up to 4 power sensors on one R&S NRP base unit simultaneously
    * Flexible measurements on up to 128 time slots per power sensor (26 time slots with base unit)
    * Direct USB connection from sensor to a PC
    * S parameter correction of components between sensor and test object
    * 2 years calibration cycle for base unit as well as for the sensors

Small dimensions (WxHxD) 274 mm x 112 mm x 267 mm

Low weight < 3.0 kg
Related Products

    * R&S NRP-Z Sensors





 
ModelSKUDescription
DCV-10240.2187.06Documentation
of calibration values
NRP-B11146.9008.02Option:
Sensor check source
NRP-B21146.8801.02Option:
Second sensor input (B) (factory-fitted only)
NRP-B31146.8501.02Option:
Battery supply with built-in charger and NiMH battery
NRP-B41146.9308.02Option:
Ethernet LAN interface 10/100 Base-T
NRP-B51146.9608.02Option:
3rd and 4th sensor input (C,D) (B2 required)
NRP-B61146.9908.02Option:
Rear-panel sensor inputs A and B. Not in conjunction with NRP-B5
NRP-Z111138.3004.02Average
power sensor for universal use, 10 MHz - 8 GHz, 200 pW - 200 mW,
NRP-Z21146.6750.05Sensor
extension cable to 5 meters
NRP-Z21146.6750.10Sensor
extension cable to 10 meters
NRP-Z211137.6000.02Average
power sensor for universal use 10 MHz - 18 GHz, 200 pW - 200 mW,
NRP-Z221137.7506.02Average
power sensor 10 MHz - 18 GHz, 2 nW - 2 W for universal use,N(m)
NRP-Z231137.8002.02Average
power sensor 10 MHz - 18 GHz, 20 nW - 15 W for universal use, N(m)
NRP-Z241137.8502.02Average
power sensor 10 MHz - 18 GHz, 60 nW - 30 W for universal use, N(m)
NRP-Z31146.7005.02USB
adapter (active) for NRP-Z sensors, including trigger output and AC
supply
NRP-Z41146.8001.02USB
adapter (passive) for NRP-Z sensors powered via USB
NRP-Z511138.0005.02Thermal
power sensor 0 - 18 GHz, 1 µW - 100 mW, N(m)
NRP-Z551138.2008.02Thermal
power sensor 0 - 40 GHz, 1 µW - 100 mW, 2.92mm(m)
NRP-Z811137.9009.02Wideband
Power Sensor 50MHz to 18GHz; 1nW to 100mW. 30MHz video bandwidth,
NRP-Z911168.8004.02Average
power sensor 9 kHz - 6 GHz, 200 pW - 200 mW, N(m)
NRP-C31143.8500.02.C3Three
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 1 additional depot calibration(s).
NRP-C51143.8500.02.C5Five
years of calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 2 additional depot calibration(s).
NRP-R31143.8500.02.R3Three
years of depot repair coverage, including recalibration and test data if
necessary to complete the repair. First year of repair coverage is
provided by the 12-month new product warranty.
NRP-R51143.8500.02.R5Five
years of depot repair coverage, including recalibration and test data if
necessary to complete the repair. First year of repair coverage is
provided by the 12-month new product warranty.
DCV-10240.2187.06Documentation
of calibration values
NRP-Z11-C31138.3004.02.C3Three
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 1 additional depot calibration(s).
NRP-Z11-C51138.3004.02.C5Five
years of calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 2 additional depot calibration(s).
NRP-Z11-R31138.3004.02.R3Three
years of depot repair coverage, including recalibration and test data if
necessary to complete the repair. First year of repair coverage is
provided by the 12-month new product warranty.
NRP-Z11-R51138.3004.02.R5Five
years of depot repair coverage, including recalibration and test data if
necessary to complete the repair. First year of repair coverage is
provided by the 12-month new product warranty.
NRP-Z111138.3004.04Power
sensor 10 MHz - 8 GHz, 200 pW - 200 mW with a short cable (0.4 m)
DCV-10240.2187.06Documentation
of calibration values
NRPZ21-C31137.6000.02.C3Three
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 1 additional depot calibration(s).
NRPZ21-C51137.6000.02.C5Five
years of calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 2 additional depot calibration(s).
NRPZ21-R31137.6000.02.R3Three
years of depot repair coverage, including recalibration and test data if
necessary to complete the repair. First year of repair coverage is
provided by the 12-month new product warranty.
NRPZ21-R51137.6000.02.R5Five
years of depot repair coverage, including recalibration and test data if
necessary to complete the repair. First year of repair coverage is
provided by the 12-month new product warranty.
DCV-10240.2187.06Documentation
of calibration values
NRP-Z22-C31137.7506.02.C3Three
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 2 additional depot calibrations
NRP-Z22-C51137.7506.02.C5Five
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 4 additional depot calibrations
NRP-Z22-R31137.7506.02.R3Three
years of depot repair coverage, including recalibration and test data if
necessary to complete a repair - 1st year of repair coverage is
provided by the 12-month new product warrant
NRP-Z22-R51137.7506.02.R5Five
years of depot repair coverage, including recalibration and test data if
necessary to complete a repair - 1st year of repair coverage is
provided by the 12-month new product warranty
NRP-Z23-C31137.8002.02.C3Three
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 2 additional depot calibrations
NRP-Z23-C51137.8002.02.C5Five
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 4 additional depot calibrations
NRP-Z23-R31137.8002.02.R3Three
years of depot repair coverage, including recalibration and test data if
necessary to complete a repair - 1st year of repair coverage is
provided by the 12-month new product warranty
NRP-Z23-R51137.8002.02.R5Five
years of depot repair coverage, including recalibration and test data if
necessary to complete a repair - 1st year of repair coverage is
provided by the 12-month new product warranty
NRP-Z24-C31137.8502.02.C3Three
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 2 additional depot calibrations
NRP-Z24-C51137.8502.02.C5Five
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 4 additional depot calibrations
NRP-Z24-R31137.8502.02.R3Three
years of depot repair coverage, including recalibration and test data if
necessary to complete a repair - 1st year of repair coverage is
provided by the 12-month new product warranty
NRP-Z24-R51137.8502.02.R5Five
years of depot repair coverage, including recalibration and test data if
necessary to complete a repair - 1st year of repair coverage is
provided by the 12-month new product warranty
NRP-Z271169.4102.02Power
sensor module DC to 18GHz, N(m) (for FSMR)
NRP-Z281170.8008.02Level
Control Sensor 10MHz to 18GHz,N(m) (for signal generators)
NRP-Z311169.2400.02Power
Sensor for universal use. 10MHz to 33GHz; 200pW to 200mW, 3.5mm(m)
NRP-Z3111171.8601.02Average
Power Sensor. 10MHz to 22GHz; 200pW to 200mW
NRP-Z371169.3206.02Power
sensor module DC to 26.5GHZ, 3.5mm(m) (for FSMR)
NRP-Z37-C31169.3206.02.C3THREE
YEARS OF DEPOT CALIBRATION COVERAGE BASED ON THE R & S RECOMMENDED
CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS
INCLUDED WITH PRODUCT DELIVERY WITH 1 ADDITIONAL DEPOT CALIBRATION(S).
NRP-Z37-C51169.3206.02.C5FIVE
YEARS OF DEPOT CALIBRATION COVERAGE BASED ON THE R & S RECOMMENDED
CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS
INCLUDED WITH PRODUCT DELIVERY WITH 2 ADDITIONAL DEPOT CALIBRATION(S).
NRP-Z37-R31169.3206.02.R3THREE
YEARS OF DEPOT REPAIR COVERAGE INCLUDING RE-CALIBRATION IF NECESSARY TO
COMPLETE REPAIR. THE FIRST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE
12-MONTH NEWPRODUCT WARRANTY.
NRP-Z37-R51169.3206.02.R5FIVE
YEARS OF DEPOT REPAIR COVERAGE INCLUDING RE-CALIBRATION IF NECESSARY TO
COMPLETE REPAIR. THE FIRST YEAR OF REPAIR COVERAGE IS PROVIDED BY THE
12-MONTH NEWPRODUCT WARRANTY.
NRP-Z41146.8001.04USB
adapter (passive) for NRP-Z sensors with a short cable (0.4 m)
NRP-Z51-C31138.0005.02.C3Three
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 2 additional depot calibration(s).
NRP-Z51-C51138.0005.02.C5Five
years of calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 4 additional depot calibration(s).
NRP-Z51-R31138.0005.02.R3Three
years of depot repair coverage, including re-calibration if necessary to
complete the repair. First year of repair coverage is provided by the
12-month new product warranty.
NRP-Z51-R51138.0005.02.R5Five
years of depot repair coverage, including re-calibration if necessary to
complete the repair. First year of repair coverage is provided by the
12-month new product warranty.
NRP-Z521138.0505.18Thermal
power sensor. 0 to 18GHz; 1µW to 100mW, 3.5mm(m)
NRP-Z55-C31138.2008.02.C3Three
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 1 additional depot calibration(s).
NRP-Z55-C51138.2008.02.C5Five
years of calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 2 additional depot calibration(s).
NRP-Z55-R31138.2008.02.R3Three
years of depot repair coverage, including re-calibration if necessary to
complete the repair. First year of repair coverage is provided by the
12-month new product warranty.
NRP-Z55-R51138.2008.02.R5Five
years of depot repair coverage, including re-calibration if necessary to
complete the repair. First year of repair coverage is provided by the
12-month new product warranty.
NRP-Z81.C31137.9009.02.C3Three
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 2 additional depot calibration(s).
NRP-Z81.C51137.9009.02.C5Five
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 4 additional depot calibration(s).
NRP-Z81.R31137.9009.02.R3Three
years of depot repair coverage, including re-calibration if necessary to
complete the repair. First year of repair coverage is provided by the
12-month new product warranty.
NRP-Z81.R51137.9009.02.R5Five
years of depot repair coverage, including re-calibration if necessary to
complete the repair. First year of repair coverage is provided by the
12-month new product warranty.
NRP-Z91-C31168.8004.02.C3Three
years of depot calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 1 additional depot calibration(s).
NRP-Z91-C51168.8004.02.C5Five
years of calibration coverage based on the R&S recommended
calibration interval - includes test data. The first calibration is
included with product delivery with 2 additional depot calibration(s).
NRP-Z91-R31168.8004.02.R3Three
years of depot repair coverage, including re-calibration if necessary to
complete the repair. First year of repair coverage is provided by the
12-month new product warranty.
NRP-Z91-R51168.8004.02.R5Five
years of depot repair coverage, including re-calibration if necessary to
complete the repair. First year of repair coverage is provided by the
12-month new product warranty.
NRP-Z921171.7005.02Average
power sensor 9kHz - 6GHz, 2nW - 2W, N(m)
NRP-Z921171.7005.42Average
power sensor 9kHz - 6GHz, 2nW - 2W, N(m)
NRP-Z981170.8508.02Level
Control Sensor 9kHz to 6GHz, N(m) (for signal generators)

  • Manufacturer: Rohde Schwarz
  • Model: NRP
Please fill out the form below for more information about this product.

* Required Information

 *
 *






 *





This message is included with all emails sent from this site: IMPORTANT: For your protection and to prevent malicious use, all emails sent via this web site are logged and the contents recorded and available to the store owner. If you feel that you have received this email in error, please send an email to sales@testequipmentconnection.com
Americas

United States USA & Canada: (800) 615-8378
 Florida: (407) 804-1299
Mexico Mexico 52-55-8421-4127
Chile Chile: 2-897-4335
Brazil Brazil: 301-32793
 Fax: 800-819-8378 / 407-804-1277
Skype: TestEquipmentConnection

Test Equipment Connection Corporation
30 Skyline Drive
Lake Mary, FL 32746 USA

TE Connection Asia, Ltd.
Unit E4, 7/F., Phase I, Kaiser Estate,
No. 41 Man Yue Street
Kowloon, Hong Kong.

Test Equipment Connection Pte. Ltd.
6 Battery Road
#31-00 Standard Chartered Bank Building
Singapore 049909

Test Equipment Connection Europe S.P.R.L.
Levels 20, Bastion Tower
5 Place du Champ de Mars
B-1050 Brussels
Belgium
+32 (2)808 0820

National Association of Government Contractors
Europe
United Kingdom United Kingdom: 20-8144-7837
Ireland Ireland: 1-442-8376
Sweden Sweden: 46-46-288-61-42
Denmark Denmark: 369-92915
Finland Finland: 358-9-2316-3837
Asia/Pacific

China China: 86-136-3217-2095
Hong Kong Hong Kong: 852-2690-1360
Singapore Singapore: 65-6320-8596
Australia Australia: 61-2-8011-3687
Skype: TEConnectionAsia

GSA Contract # GS-07F-0358U
FSC Code: 66 II J
NAICS category #334515
CAGE Code: 023Y7

© 2008 Test Equipment Connection. Powered by Zen Cart